Indirect Copper Cylinders (Double Feed)
to BS 1566: Part 1: 2002 (Gravity Type)

Back to Cylinders
 

B.S.
Ref.
Size (mm) Approx. Imperial
Size (inches)
Min. Storage
Capacity
Height of Screwed
Connections
Height(A)xDia(B) Ltrs Appx.
Galls.
H L M
1 900x350 36x14 72 16 700 100 400
2 900x400 36x16 96 21 700 100

400

3 1050x400 42x16 114 25 800 100

470

4 675x450 27x18 84 18 450 100

300

5 750x450 30x18 95 21 550 100

340

6 825x450 33x18 106 23 625 100

370

7 900x450 36x18 117 26 700 100

400

8 1050x450 42x18 140 31 800 100

470

9 1200x450 48x18 162 35 950 100

540

9E 1500x450 60x18 206 45 1200 100

620

10 1200x500 48x20 190 42 950 150

540

11 1500x500 60x20 245 54 1200 150

670

12 1200x600 48x24 280 61 950 150

540

13 1500x600 60x24 360 79 1200 150

670

14 1800x600 72x24 440 97 1350 150

800


Indirect Copper Cylinder diagram
The coil heat exchangers are designed for reheat time to 60oC (140oF) In 40 minutes, by gravity circulation at 82oC (180oF), 20 minutes if by pumped circulation
N.B. Dimensions do not include the insulation.
*Extra Available on request

 
Kitemark Licence No.KM07451 BS. Ref. 4-9E

Uncomplicated Quality and Value
Copper Cylinder Manufacturers

Powerflow 2000 Unvented Cylinder
Thermflow Thermal Store
Heat Pump Cylinders
Open Vented Hot Water Cylinders
Wet Electric System - Electraflow
Calorifiers
Plateflow Hot Water Cylinder
Renewable How Water Cylinders
Timesaver Plumbing Unit
Fastheat
Backboilers
Spares for Hot Water Cylinders

Hot Water Cylinders Helpline from McDonald Engineers

Hot Water Cylinder Standards from McDonald Engineers